LATEST UPDATES

Thursday 19 January 2023

Different Grades of Concrete -- Concrete Mix Design

Different grades of Concrete:

Grades of Concrete
          Based on different concrete mix proportions (or) mix ratio’s, concrete mixer is divided into different grades. As per IS 456:2000, concrete mix design has the following mix proportions:

Type of Concrete

Concrete Grade

Mix Ratio (or) Proportion

Characteristic
Compressive strength of
Concrete
@ 28 Days in N/mm2

Ordinary concrete

M5

1:5:10

5 N/mm2

M7.5

1:4:8

7.5 N/mm2

M10

1:3:6

10 N/mm2

M15

1:2:4

15 N/mm2

M20

1:1.5:3

20 N/mm2

Standard Concrete

M25

1:1:2

25 N/mm2

M30

Design Mix

30 N/mm2

M35

Design Mix

35 N/mm2

M40

Design Mix

40 N/mm2

M45

Design Mix

45 N/mm2

M50

Design Mix

50 N/mm2

High Strength
Concrete

M55

Design Mix

55 N/mm2

M60

Design Mix

60 N/mm2

M65

Design Mix

65 N/mm2

M70

Design Mix

70 N/mm2


Note:-

In Example: M5

M represents "Mix"

5 represents the compressive strength achieved after 28 days of curing.

Concrete Mix Design



Friday 16 December 2022

నోట్ ఫైల్ --- సమర్పణ

                                                                                                         ఆర్. .సి .o  . 270/2021-1

సమర్పణ : 

--- పురపాలక సంఘము - -------వ ఎన్నికల వార్డు, ----- కాలనీ  నందు త్రాగునీటి  పైపు లైన్ లేక  ఆ ప్రాంత ప్రజలకు త్రాగునీరు కొరకు చాలా ఇబ్బందిగా ఉన్నదని, కావున సదరు  ప్రాంతము నందు పైపు లైన్  వేసి త్రాగునీరు  సౌకర్యము కల్పించవలసినదిగా వార్డు కౌన్సిలరు గారు అర్జీ ద్వారా కొరియున్నారు. అందుపై, ఎగ్జిక్యూటివ్ అథారిటీ వారి ఆదేశములు ననుసరించి, ఇంజనీరు గారి సదరు ప్రాంతమునకు తనిఖిచేసి ఇ.నెo. -------- నుండి ఇ.నెo. ------  వరకు 110 mm dia hdpe పైపులైన్ వేయుటకు గాను అంచనా మొత్తము రూ.----.00 లక్షలు అగునని ఇంజనీరు గారు ప్రతిపాదనలు నందు తెలిపియున్నారు. కావున, ఆ ప్రాంత ప్రజలకు త్రాగునీరు అత్యవసర దృష్ట్యా సదరు మొత్తము మున్సిపల్ సాదారణ నిధులు నుండి చెల్లించుటకు గాను కౌన్సిల్ వారి నిరీక్షణ లోబడి చైర్ పర్సన్ గారి ముందస్తు ఆమోదమునకు ఉంచడమైనది.



      అసిస్టంట్ ఇంజనీర్,                             డిప్యూటీ అసిస్టంట్ ఇంజనీర్                                కమిషనర్,                                     చైర్ పర్సన్

 ------- పురపాలక సంఘము               ------- పురపాలక సంఘము                 ------- పురపాలక సంఘము          ------- పురపాలక సంఘము

 


        నోట్ ఫైల్ --- త్రాగునీటి  పైపు లైన్



        


Monday 12 December 2022

THE ANDHRA PRADESH GAZETTE on ORDINANCE TO PROVIDE A STATUTORY FRAMEWORK FOR THE GRAMA SACHIVALAYAMS AND WARD SACHIVALAYAMS

 ANDHRA PRADESH ACTS, ORDINANCES AND REGULATIONS Etc.,

The following is the authoritative text in English Language of the Ordinance promulgated by the Governor on the 5th December, 2022 is being published under Article 348(3) of the Constitution of India for general information:- 

ANDHRA PRADESH ORDINANCE No. 15 OF 2022. 

Promulgated by the Governor in the Seventy Third Year of the Republic of India. 

AN ORDINANCE TO PROVIDE A NEW STRUCTURE TO DELIVER INNUMERABLE OTHER CITIZEN CENTRIC SERVICES AND AMENITIES INCLUDING THE INDICATIVE LIST OF CITIZEN SERVICES MENTIONED IN THE 11TH SCHEDULE AND 12 TH SCHEDULE OF THE CONSTITUTION OF INDIA AND TO PROVIDE A STATUTORY FRAMEWORK FOR THE GRAMA SACHIVALAYAMS AND WARD SACHIVALAYAMS AND FOR MATTERS CONNECTED THEREWITH OR INCIDENTAL THERETO.

THE ANDHRA PRADESH GAZETTE Copy

గ్రామ వార్డు సచివాలయంలకు ఒక చట్టబద్ధమైన స్వరూపాన్ని ఇచ్చుట


Saturday 10 December 2022

STANDARD CONVERSION FACTORS USED IN CONSTRUCTION FIELD

          A civil engineer on site must learn some basic conversions. Here we are provided some basic measurements and conversion factors which are generally used on site. Hope it will help you in work.

Units

Conversion Factor

1 meter

3.28 Feet

1 meter

39.37 inches = 1.09 Yards

1 meter

100 cm

1 meter

1000 mm

1 foot

12 inches

1 inch

2.54 cm = 25.4 mm

1 chadaram

100 sq feet

1 inch

8 soot

 

Units

Conversion Factor

1 Bag of cement

0.0347 cum

1 Sq m

10.76 sq ft

1 acre

43560 sq. ft = 4046.46 sqm

1 ltr 

 0.22 Gal

 1 gallon

4.546 ltr 

 1 cu ft

28.317 ltr 

 1 cu ft 

0.028 cu mtr 

 1 cu ft 

6.24 gallons 

 



CLEAR COVER FOR DIFFERENT R.C.C. MEMBERS

What Is Clear Cover (or) Cover in Concrete?

The clear cover (or) Cover in RCC, is the distance between the exposed concrete surface (without plaster and other finishes) to the nearest surface of the reinforcement bar i.e., Steel rod.

Mostly, it is known as "clear cover" or "minimum concrete cover" in general terms on a construction site.

Why clear cover is important?

Cover is provided to protect the reinforcing bar (rebar) from corrosion due to weather and fire. If we don't leave a cover, then the reinforcing bar will stick to the surface of the shuttering and cause rust in the bar after we casting the column or beam and also damage the strength of the column or beam.

For example, in the case of fire in a building, the metal begins to melt and lose its strength. Therefore, the clear cover acts as an insulator and prevents from melting.

This gives more strength to the bars, reduces the chances of slipping and also increases the durability of the bars. This provides adequate embedding for the reinforcing bars to withstand stress without loss of grip.


How to Define Nominal Cover

As per IS 456(Clause 26.4.1), the term clear cover has been replaced by the term Nominal cover.

The nominal cover is the distance between the exposed concrete surface to nearest reinforcement bar ( it can be any bar I.e., main bar, longitudinal bar and even links or stirrups).

What Is Effective Cover in Concrete?

The Effective cover is the distance measured betweenthe exposed concrete surface (without plaster and other finishes) to the centre of the area ( centroid ) of reinforcement, i.e., tension or compression reinforcement. 

Effective cover = overall depth – effective depth.    (Or)

Effective cover = Clear cover + Diameter of Stirrup + (Diameter of main reinforcement bar ÷ 2).


Member

Clear cover (Normal Conditions)

wet climatic environment or sea side location

Foundation

75 mm

 

Raft Foundation

Top = 50 mm

Bottom = 75 mm

Sides = 75 mm

 

Strap Beam

50 mm

 

Beam

25 mm

35 to 40 mm

Column

40 mm

50 mm

Flat Slab

20 mm

 

Slab

15 mm

 

 

 



@2020 All Rights Reserved. Designed by WWW.SMARTWAYTOSTUDY.COM !!!! Sitemap !!!! Blogger Templates